| Lithium Ion Chargers The Model 6040 uses a low voltage input, generated by a wall mounted transformer, with a power envelope of 30 watts. The bulk charge current is then determined by dividing the battery voltage into 30, with a current limitation of 2.5 amps. The low voltage input is determined by the voltage of the battery to be charged. The unit is available for domestic use with a wall transformer using 120 VAC, 60 Hz. However, other voltage and frequency transformers are available upon request. |
|
To specify the charger, select the appropriate model as before, then the number of cells, finally the constant current charge current. Use the format: AAAA-B-CC-DDD AAAA is the model number, such as 6040. B is the cell count, from one to four. CC is the constant current charge current, and DDD is the AC voltage the external transformer must operate with, 115 or 230. For a Model 6040, charging 2 MP 144350 cells in series, operating from 115 VAC, the specification would read: 6040-2-10-115 |
|
|
||