You are here

PB-LWH-04-01 Land Warrior Battery - High Capacity, Low Operating Temperature

Rechargeable Lithium-Ion Battery

14.8V, 11.6Ah, 171Wh
PB-LWH-04-01 Land Warrior Battery - High Capacity

Typical Applications

  • Military Training Systems
  • Back-up Server Power
  • Rugged, Portable Electronics

Standards Compliance

  • SMBus v 1.1 smart battery technology compliant
  • SBD v 1.1 smart battery dataset compliant
  • MIL-STD-810G compliant
  • MIL-STD-461F (EMI) compliant
  • UN/DOT Transportation 38.3 T1-T8 compliant
  • Manufactured under ISO 9001:2008 certified quality system

Key Features

  • Charging, discharging and SMBus capabilities available via the connector or flat contacts
  • Charging and SMBus capabilities, only, available via flat contacts
  • Flat contacts are isolated, until placed in the approved battery charger to allow battery charging
  • Low operating temperature (-30°C / -22°F)
  • 5-segment State-of-Charge (SOC) display
  • High energy density
Model No PB-LWH-04-01
NSN TBD
Voltage Range

10.0V min.; 14.8V nom.; 16.8V max.

Nominal Capacity

11.6 Ah @ 500mA @ 23°C (74°F)

Maximum Discharge

5.0 A continuous @ 23°C (74°F)

Max. Pulse Discharge

6.0 A for 5 seconds @ 23°C (74°F)

Energy 171 Wh
Energy Density 171 Wh/kg, 269 Wh/l
Weight 998 grams (2.2 lbs.)
Cycle Life > 300 cycles @ C/5 to 80% of initial capacity @ 100% depth of discharge
Operating Temperature -30°C to +60°C (-22°F to +140°F)
Storage Temperature -20°C to +50°C (-4°F to +122°F)
Self-Discharge < 3% per month @ 25°C (77°F)
Housing Hard plastic, black, lusterless, UL 94 V-0, NORYL
Mating Connector Glenair 8070-1000-07Z16-7SN (Stainless Steel)
Communications
  • SMBus v1.1 communication protocol
  • SBD v1.1 data set support
Contacts Copper alloy with gold plating over nickel plating
State of Charge Indicator 5-Segment LCD Display
Safety See Safety Data Sheet – SDS055
Transportation See Safety Data Sheet – SDS055
Harmonized Tariff Code 8507.60.0020
Battery Charging Charge at constant voltage of 16.8 Volts in a temperature range of 0°C to 45°C (32°F to 113°F), limiting current to 3.0 A max, at 23°C, until current declines to 200 mA.
Charging Method The battery should be charged using a constant current/constant voltage (CC/CV) charging method.
PB-LWH-04-01 Land Warrior Battery - High Capacity Drawing
  • PC-6010-02  1-bay tactical portable smart charger
  • PC-6805  8-bay tactical portable smart charger
  • PC-3200M/C  32-station bulk smart charger